Professional dosing and control system POOL GUARD MAX PH / RX / T / CL free / CL total (SONDA CL)

Automatic POOL GUARD MAX PH / RX / T / CLfree / CLtotal system for proportional dosing and control of PH, Rx levels, free and total chlorine concentrations.

POOL GUARD MAX PH / RX / T / CL free / CL total (SONDA CL) - a professional automatic proportional dosing and control system levels of PH, RedOx, concentrations of free (CL free ) and total chlorine (CL total ) in water for swimming pools.

The dosing system is controlled by the liquid flow sensor, in the absence of flow the system goes into standby mode.

BASIC ADVANTAGES: two controllers of the new generation eSELECT-B2 with a color LCD 4 ”, a russified menu, a wide selection of additional settings, an easily accessible flow-through harness for servicing.

Dosing system POOL GUARD MAX PH / RX / T / CL free / CL total (SONDA CL) is supplied mounted on a chemical-resistant plastic panel (900x600x8 mm), in full kit, ready for installation and commissioning.

SPECIFICATIONS:

  • At the heart of the system are two liquid analyzers of the eSELECT-B2 series, with two independent pH / RedOx / Cl parameters, each with a universal input power supply of 90-260V; DLX-CC / M series proportional metering pumps and two potentiostatic sensors for free (0-2 mg / l) and total (0-20 mg / l) SONDA CL chlorine (organic / inorganic chlorine).
  • Dosing delay when the system is turned on.
  • Level sensor or flow sensor alarm.
  • Alarm settings for pH / Cl (MIN / MAX) concentration limits.
  • Dosage regimen: proportional to PROP.
  • PT100 temperature sensor support.
  • Automatic pH temperature compensation.
  • Pump productivity: PH: 5 l / h; Cl: 15 l / h.
  • Alarm ON / OFF (proximity switch) outputs.
  • Electronic blocking of the settings made.
  • Built-in electronic journal of accounting for changes in measured parameters (option).
  • Measuring ranges: 0-14 pH; -1000 + 1400 mV; free chlorine 0-2 mg / l, total chlorine 0-20 mg / l, 0-100 ° C.
  • Two independent outputs ON / OFF (proximity switch) for each measured parameter.
  • Two independent 4-20 mA outputs per Set Point.
  • Electronic clock (time, date), timer.
  • Four programmable ON / OFF (contactless relay) outputs for connecting a pump for dosing of flocculant or installation of « shock » chlorination timer.
  • Two 4 ” color LCD displays.
  • RS 232 output (RS 485 via adapter - optional) for PC.
  • Dust and moisture protection class of the controller and pumps: IP65.
  • Easily accessible flow line for servicing.
  • Russified menu.

DOSING SYSTEM CONFIGURATION: (SONDA CL + SONDA CL TOTAL) - configuration with potentiostatic sensors for free and total chlorine (organic / inorganic chlorine.

Composition of the dosing system:

1 pc. - pump DLX-CC / M 5-7 230V PVDF.
1 pc. - DLX-CC / M 15-4 230V PVDF pump.
2 pcs. - ESELECT-B2 230V fluid analyzer.
1 pc. - chlorine sensor SONDA CL, FIC / FOC, 0-2 mg / l.
1 pc. - chlorine sensor SONDA CL, TC, 0-20 mg / l.
2 pcs. - connecting cable for SONDA CL.
2 pcs. - reagent injection valve.
2 pcs. - reagent intake valve.
1 pc. - PH level sensor with 0.5 m cable.
1 pc. - RX level sensor with 0.5 m cable.
1 pc. - temperature sensor PT100, PVC.
2 pcs. - reagent level sensor with cable 2 m.
2 pcs. - sensor holder PH-CL (FS) with mounting kit.
1 pc. - calibration solution PH 7, 55ML.
1 pc. - calibration solution PH 9, 55ML.
1 pc. - calibration solution 650 mV, 55ML.
2 pcs. - reagent intake hose, 4x6, PVC, 2 mp.
2 pcs. - reagent discharge hose, 4x6, PE, 2 m.p.
1 pc. - mounting plate 900x600x8 mm.
1 pc. - set of installation and maintenance instructions.

Type Performance,
l / h
Pressure,
bar
pH RX
CL Price without VAT, (€)
POOL GUARD MAX PH / RX / T / CL free / CL total
(SONDA CL)
5
15
7
4
0 … 14 - 1000 +1400 mV 0 ÷ 2 ppm
0 ÷ 20 ppm
7035